11.2 SeedEye box

Figure 1.

  1. Integrated CAN BUS connector (previous/next CAN device)

    TE Superseal 4-pin male connector

  2. Integrated X-LiNE BUS connector (sensor connection)

    TE Superseal 4-pin male connector

  3. LED lights for RGB control

    Power in/CAN bus/X-LiNE BUS/power out

  4. Attachment point

    M7 Screw

Table 1. LED light status

Power IN

CAN BUS

X-LiNE BUS

Power OUT

LED #

A

B

C

D

GREEN

Input voltage OK

Connected

Connected sensors

Output voltage OK

ORANGE

Not used

Waiting for connection

Steady glow: no sensors detected

Flashing: problem with sensor detection1

Not used

ORANGE/BLUE

Not used

Not used

Sensors in start-up mode detected2

Not used

RED

Low input voltage

CAN BUS error

X-LiNE BUS error

Low output voltage

BLUE

Software update

1 Orange flashing LED may indicate one of the following:a. Address conflict between sensors (sensors with identical saved addresses connected).b. The addresses of the detected sensors are not continuous.c. Sensor without valid address detected.
2 Some of the connected sensors are in start-up mode (in which case the LEDs for these sensors are blue). Update the sensor software to rectify this.