19.3 Alarm Work Station (WS625)
When an alert that affects Work Station (WS625) happens, the alarm is shown as a red high-intensity LED which flashes x times, then waits 4 seconds before recommencing the sequence. Should several alerts occur simultaneously, only the alert with the highest priority is displayed. x = 1 has the highest priority
|
LED |
Error |
|---|---|
|
Green (A) |
Logic supply voltage OK |
|
Yellow (B) |
CAN traffic, blinking during traffic |
|
Red (C) |
Error, see Table 2 |
|
Green (D) |
Power supply OK |
|
No. blinks |
Error |
|---|---|
|
1 |
Low logic supply voltage |
|
2 |
Low power supply voltage |
|
3 |
Faulty motor power (Polyswitch) |
|
4 |
Overload protection tripped (software controlled) |
|
5 |
Thermal MOSFET protection tripped |
|
6 |
Card temperature too high |
|
7 |
Card temperature too low |
|
8 |
CAN communication fault |