11.5.2 Flow sensitivity
Set the sensitivity of the sensors for when they should issue warnings regarding low flow (no. 580) .
The default value for the flow sensitivity is set to 50 %. The sensitivity value can be updated to any percentage between 0-99%.
Sensitivity value 0% corresponds to the lowest sensitivity level.
Sensitivity value 99% corresponds to the highest sensitivity level.
The value is based on the seed output rate and the tractor speed and should be updated manually in accordance with this to achieve the correct level of flow sensitivity.
Recommended start values, flow sensitivity
Rapeseed: 25–35 %
Corn: 70–80 %
Wheat: 70–80 %
Peas: 60–70 %
Oats: 70–80 %
The setting only affects the sensitivity for when low flow (no. 580) is detected by the sensor.
The high flow alarm (no. 1060), partly blocked (no. 560), completely blocked (no. 570) and low flow section (no. 1070) are not affected by this percentage.