7.4 Radar

Figure 1. Calibration of radar

Fields on the screen:

  1. Shows the total number of radar pulses during calibration.

  2. Shows the calibration result as number of pulses/m.

  3. Field to enter the distance driven when calibrating.

  4. Resets and starts the measurement.

  5. Finishes the calibration sequence.

Calibrating the radar:

  1. Measure an optional distance (at least 100 m).

  2. Press (D) at the starting point to begin measuring.

  3. Press (E) once the measured distance has been covered.

  4. Press the (C) field and enter the distance covered in metres. The number of pulses per metre of driving distance is calculated and automatically updated in the (B) field.

Note

Alternatively, you can drive the measured distance with the machine lowered to the drilling position and stop the machine at the end point of the distance. Enter the distance covered in field (C) and exit the calibration menu.