7.4 Lift Control

Figure 1.

Settings

Setting the level for the drilling position and the LowLift position, as well as setting the levels for output start and output stop.

  1. Lift height. The machine’s momentary height.

  2. LowLift level. The set value is a percentage of the level for a fully raised machine, which is 100.

  3. Level for output start. The level at which the seed meter begins feeding out seed when the machine is lowered into the drilling position. The default values are the relative current values for the LowLift and drilling positions (for the machines where they are available). If the LowLift or drilling positions are changed, the output start level will also be adjusted.

  4. Level for output stop. The level at which the seed meter stops feeding out seed when the machine is raised to the LowLift position. The default values are the relative current values for the LowLift and drilling positions (for the machines where they are available). If the LowLift or drilling positions are changed, the output start level will also be adjusted.

  5. Indicator arrows.

Adjustment

  1. Press the button for the function to be set in the field with the height scale.

  2. Raise or lower the drill unit to the desired position using the hydraulic lever. The indicator arrow (E) follows the drill unit’s movement along the height scale.

  3. Confirm the value between each setting.

    and can never be higher than .

    can never be higher than .