12.2 Alarm list

10 Fan, low rev

Check whether the hydraulic hoses are connected correctly to the tractor.

Check that the flow of hydraulic oil from the tractor is correctly adjusted.

Check the programmed alarm limit settings in the control unit.

Check the rotation speed sensor cable, connectors and connections.

Check the sensor function by spinning the fan wheel manually and checking the sensor LED. The LED should light up when the pin on the fan shaft passes by. The distance between the sensor and the indicator plate must be 1–2 mm. Adjust if necessary. A lit LED, however, is not necessarily any guarantee that the sensor is operating.

If the alarm only appears occasionally, this is probably because the sensor is either incorrectly adjusted or defective.

11 Fan, high rev

Check that the flow of hydraulic oil from the tractor is correctly adjusted.

Check the programmed alarm limit settings in the control unit.

21 Seed meter LH is not rotating

If the seed meters do not move:

Check the power supply to the metering unit.

Check the cabling..

If the alarm appears despite the metering units rotating:

Check what alarm time has been programmed.

Check the cables, contacts and connection.

Check the operation of the sensor.

The sensor LED should light when the toothed plate passes. The distance between the sensor and the pulse disc must be 2.5 +/- 0.25mm. Adjust if necessary. An illuminated diode is no guarantee that the sensor is working properly.

Check the condition and installation of the toothed plate.

22 Seed meter RH is not rotating

See alarm no. 21.

23 The seed output unit is not rotating

See alarm no. 21.

30 BioDrill seed feed is not rotating

See alarm no. 21.

60 Low level seed

Check the seed level in the hopper.

If there is seed in the hopper:

Adjust the sensitivity of the sensor.

The alarm is triggered if the machine has a level guard.

Check the sensor’s cable, contacts and connections.

Check that the sensor is not dirty or damp. Wipe the sensor clean with a dry cloth.

The sensor may be defective.

61 Low level LH seed

See alarm no. 60.

62 Low level RH seed

See alarm no. 60.

63 Low level, seed

See alarm no. 60.

70 Low level, BioDrill

See alarm no. 60.

80 Max speed, seed

Perform a new calibration.

Check power supply to WorkStation.

Inspect the condition of the cable and connectors. The green indicator lamp on WorkStation shows that voltage is present, but the lamp is working even though the intermediate cable is partly damaged.

90 Max speed, BioDrill

Se alarm no. 80.

181 LH tramlining

The alarm is triggered if the tramlining hatches are closed when they should be open.

Check the function of the tramlining units in the distributor head, motor, turntable, springs and hatches. Clean as required.

Check the wiring, connectors and connections of the sensor.

Check the sensor.

182 RH tramlining

Se alarm no. 181.

183 Tramlining, both

Se alarm no. 181.

190 No speed

The alarm is triggered is there are no radar pulses, despite the machine being lowered in the sowing position.

Check the radar settings.

Check the radar’s wiring, connectors and connections.

200 Feed stop

The alarm is triggered if the Low-Lift level has not been achieved within the preset time interval. The time interval is 10 secs.

Lower the LowLift level or increase the hydraulic pressure from the tractor.

270 Interruption to communication

The alarm is triggered if Gateway has lost communication with the terminal for an unknown reason. For example, if the terminal has been switched off or the iPad has been out of Wi-Fi range.

Acknowledge the alarm in the alarms menu. Feed stops

If the fault recurs:

Check the cabling for supply voltage to the terminal and the cabling between Gateway and the terminal.

If the iPad is not communicating with the dock, check whether Bluetooth is activated.

290 Motor fault, fertiliser

Is the hydraulic oil flow sufficient?

Does the fertiliser fan start up?

Check the fertiliser feed. Make sure that the screw turns freely and that there is no blockage in the stand pipe.

Check the air flow in the fertiliser feed while the fan is running.

Check the sensor’s cable, contacts and connections.

Check that the solenoid valve on the hydraulic block has sufficient power.

300 Low level, fertiliser

Check the level in the seed hopper.

If there is fertiliser in the seed hopper.

Adjust the sensitivity of the sensor.

Check the sensor’s cable, contacts and connections.

Check that the sensor is not dirty or damp. Wipe the sensor clean with a dry cloth.

The sensor may be defective.

310 Max. speed, fertiliser

Check the oil flow from the tractor, the hoses and couplings.

Make sure there is no blockage in the fertiliser drill.

500 Distributor head, fertiliser

Check the sensor’s cable, contacts and connections.

Check that the sensor is not dirty or damp. Wipe the sensor clean with a dry cloth.

The sensor may be defective.

510 Low fan speed

The alarm occurs when the fertiliser fan speed is lower than the configurable low fan speed for fertiliser. Has some extra requirements in order to be triggered.

511 High fan speed

The alarm occurs when the fertiliser fan speed is higher than the configurable high fan speed for fertiliser. Can always be triggered.

520 Interruption to communication

The alarm is triggered if, for some unknown reason, Gateway has lost communication with the terminal for a short period. For example, if the terminal has been switched off or the iPad has been out of Wi-Fi range.

Acknowledge the alarm in the alarms menu. Feed stops.

530 No valid serial number for the box

The system cannot find a SeedEye box to connect to.

540 Unexpected SeedEye box with serial number:

The system cannot find an expected CAN lead on the box.

550 Dust, SeedEye sensor (Row no.)

Dust/dirt in the sensor.

Clean sensor glass.

560 Partially blocked, SeedEye sensor (Row)

Sensor blocked.

Check for a blockage between sensor and seed coulter.

570 Completely blocked, SeedEye sensor (Row)

See alarm no. 560.

580 Low flow, SeedEye sensor (Row no.)

The number of detected seeds is too low.

Troubleshooting for a blockage before the sensor.

590 Incorrect number of SeedEye sensors (Expected, Found)

Make sure all sensors are correctly activated in the SeedEye settings.

Make sure all sensors in the loop are correctly connected.

591 Missing number of SeedEye sensors (Expected, Found)

Make sure all sensors are correctly activated in the SeedEye settings.

Make sure all sensors in the loop are correctly connected.

600 Lost SeedEye sensor (Row no.)

Reregister SeedEye under the SeedEye settings.

If the problem persists, make sure all detectors in the loop are correctly connected

610 Low voltage, SeedEye sensor

Ensure that the supply voltage into the SeedEye box is at least 12.0V.

620 SeedEye box timeout (serial number)

Communication error between Gateway and SeedEye box.

Ensure that the supply voltage into the SeedEye box is at least 12.0V.

Make sure the SeedEye box is correctly connected. Check cable between SeedEye box and Gateway.

621 SeedEye box timeout left (serial number)

Communication error between Gateway and left SeedEye box.

See alarm no. 620.

622 SeedEye box timeout right (serial number)

Communication error between Gateway and right SeedEye box.

See alarm no. 620.

623 SeedEye box timeout left & right (serial number)

Communication error between Gateway and left & right SeedEye box.

See alarm no. 620.

624 SeedEye box timeout fertiliser (serial number)

Communication error between Gateway and SeedEye box for fertiliser.

See alarm no. 620.

625 SeedEye box timeout left & fertiliser (serial number)

Communication error between Gateway and left SeedEye box as well as for SeedEye box for fertiliser.

See alarm no. 620.

626 SeedEye box timeout right & fertiliser (serial number)

Communication error between Gateway and right SeedEye box as well as for SeedEye box for fertiliser.

See alarm no. 620.

627 SeedEye box timeout all (serial number)

Communication error between Gateway and all SeedEye boxes.

See alarm no. 620.

628 SeedEye box timeout seed (serial number)

Communication error between Gateway and SeedEye box for seed.

See alarm no. 620.

629 SeedEye box timeout seed & fertiliser (serial number)

Communication error between Gateway and SeedEye box for seed & fertiliser.

See alarm no. 620.

630 SeedEye box bus error (serial number)

Wiring error between SeedEye box and its SeedEye detectors.

Check that contacts and cable harness, between SeedEye box and SeedEye are intact and making contact.

Now reregister the SeedEye detectors.

631 SeedEye box bus error left (serial number)

Wiring error between left SeedEye box and its SeedEye detectors

See alarm no. 630.

632 SeedEye box bus error right (serial number)

Wiring error between right SeedEye box and its SeedEye detectors

See alarm no. 630.

633 SeedEye box bus error left & right (serial number)

Wiring error between left & right SeedEye box and its SeedEye detectors

See alarm no. 630.

634 SeedEye box bus error fertiliser (serial number)

Wiring error between SeedEye box for fertiliser and its SeedEye detectors.

See alarm no. 630.

635 SeedEye box bus error left & fertiliser (serial number)

Wiring error between the left SeedEye box and its SeedEye detectors, as well as wiring error between the SeedEye box for fertiliser and its SeedEye detectors.

See alarm no. 630.

636 SeedEye box bus error right & fertiliser (serial number)

Wiring error between the right SeedEye box and its SeedEye detectors, as well as wiring error between the SeedEye box for fertiliser and its SeedEye detectors.

See alarm no. 630.

637 SeedEye box bus error all (serial number)

Wiring error between all SeedEye boxes and their SeedEye detectors.

See alarm no. 630.

638 SeedEye box bus error seed (serial number)

Wiring error between SeedEye box for seed and its SeedEye detectors.

See alarm no. 630.

639 SeedEye box bus error seed & fertiliser (serial number)

Wiring error between the SeedEye box for seed and its SeedEye detectors, as well as wiring error between the SeedEye box for fertiliser and its SeedEye detectors.

See alarm no. 630.

650 SeedEye box error in data quantity

Make sure all switches and cable harnesses are intact and are making contact.

660 SeedEye box input voltage

Ensure the power supply from the tractor is sufficient.

670 SeedEye box output voltage error

Make sure all switches and cable harnesses are intact and are making contact.

Identify which SeedEye box is faulty by looking at the LEDs on the SeedEye box and replacing this box.

720 Readdress

Error when starting the SeedEye system. Possible causes:

– One or more detectors are not connected or not powered correctly.

– One or more detectors are not registered for the relevant setting.

Check the information page to identify which detectors are issuing an alarm. Check the connection or replace the faulty detectors and readdress the system using the command in Configuration/SeedEye

740 SeedEye box power consumption

Check that wiring harness between SeedEye box and SeedEye detector is undamaged.

Disconnect a distributor head to see on which distributor head the error occurs. Continue disconnecting sections on the faulty distributor head to find out which detector is faulty. Between each disconnection, a re-registration of the SeedEye sensors is made to determine whether the fault has been corrected.

750 Voltage to the sensors too low

Make sure all switches and cable harnesses are intact and are making contact.

760 Low speed, seed

The electric motor is sitting at the lower limit for permitted speed.

Check the calibration.

Check the roller.

Check the gear.

Check the power supply.

780 Low speed, BioDrill

See alarm no. 760.

790 Signal problem from radar

Speed = 0

Check the sensor’s cable, contacts and connections.

Speed > 7.0 km/h less than 0.7 seconds

Check the sensor.

811 CAN bus error

Gateway has lost contact with the WorkStation.

Check the CAN bus cable between Gateway and WorkStation and the condition of the connectors.

821 Low voltage WorkStation

Check that the connectors and supply cables from the tractor to WorkStation are correctly connected. The flashing yellow lamp on WorkStation shows that there is power. The lamp may light even if the intermediate cable is partially damaged.

830 No LH motor pulse

If the seed meters do not move:

Check the cabling.

Check the power supply to the metering unit.

If the alarm appears although the seed meters are rotating:

Check the cabling.

840 No RH motor pulse

See alarm no. 830.

850 Old version. Update WS

Update WorkStation to version 113 or later.

860 Motor temp sensor

The temperature in the sensor is too high.

Switch off and wait until the sensor has cooled.

870 Low WS9 temperature

The machine will not start because the temperature is below the limit (-5°C) for suitable working temperature.

880 High WS9 temperature

The machine will not start or stops because the system has been overloaded.

Check the feed and clean if a stoppage has occurred.

Wait until the machine has cooled. Upper limit 80 °C.

890 Overload MOSFET

There is thermal overload of the motor.

Check the feed and clean if a stoppage has occurred.

900 Overload on WS9 Polyswitch

WorkStation is overloaded and a thermal overload fuse has tripped.

Check the feed and clean if a stoppage has occurred.

The motor can be restarted as soon as the thermal protection has cooled.

910 Overload on WS9 power

The motor is overloaded. The motor shuts down when the power supply exceeds the limit set.

Check and clean the metering unit if it has stopped.

920 Motor voltage WS9

Check all WorkStation connectors.

The green lamp on WorkStation shows that there is power. The lamp may light even if the intermediate cable is partially damaged

950 No motor pulse, BioDrill

Check the cabling, plugs and connections to the sensor.

Check the sensor. 

960 Lost sensor signal seed coulter position

See alarm no. 830.

970 Lost sensor signal front tool position

Check the cabling, plugs and connections to the sensor.

Check the sensor. 

980 Unreliable seed count

The system cannot provide a reliable value.

981 Seed count unreliable, application rate control temporarily deactivated

The system cannot observe and control the desired sown amount in seed/m2.

Drive at a more uniform speed so that the SeedEye system is given sufficient time to make its adjustments in order to reach the required rate.

982 The seed count is unreliable, the adjustment limit for sown amount has been exceeded

The system cannot observe and control the preferred sown amount in seed/m2 because the entered sown amount is set to values that are not supported or because the seed hooper is empty.

If a high sown amount or a relatively high sown amount is used, try switching gears from low to high or replacing the rotor with one with a higher sown amount (see 7.4.3 Setting the application rate). Remember to update the settings!

If a low sown amount or a relatively low sown amount is used, try switching gears from high to low or replacing the rotor with one with a lower sown amount (see 7.4.3 Setting the application rate). Remember to update the settings!

Adjust the entered application rate so that it corresponds to a permitted value.

Fill the seed hopper.

990 The SeedEye sensors have different software versions.

The SeedEye sensors have software versions which are different from one another.

Update the SeedEye software.

991 New software is available for the SeedEye sensors.

The software version used by the SeedEye sensors is incorrect.

Update the SeedEye software.

1000 The versions of the SeedEye boxes are different.

The versions of the SeedEye boxes are different.

Update the SeedEye software.

1001 New versions are available for the SeedEye boxes.

Incorrect version of SeedEye boxes.

Update the SeedEye software.

1010 Update unsuccessful.

Updating of the SeedEye boxes and sensors was unsuccessful.

Update SeedEye without re-registering the SeedEye boxes.

1050 Imbalance, seed (Left, Right)

One of the seed meters is delivering a greater amount of seed than the other seed meter.

Adjust seed output. See Calibration, 7.1 Seed. Note that calibration must be carried out with SeedEye set to Monitoring.

1060 High flow, SeedEye sensor (Row no.)

The number of counted seeds is too high.

Check for a blockage around the sensor.

Check the set value of the application rate. Too high a value will result in too many seeds passing the sensor.

1070 Low flow, section

The amount of seeds in the section is too low.

Check the level in the seed hopper.

Check for a blockage before the sensors in the section.

Activation of the ‘low flow in entire section’ function may be applicable when drilling at extremely low application rates. See 11.5 Setting blockage sensitivity and flow sensitivity.

1071 Low flow, section left

See alarm no. 1070.

1072 Low flow, section right

See alarm no. 1070.

1073 Low flow, section left and right

See alarm no. 1070.

1080 Lost contact with Universal Control

System has lost contact with external application.

Make sure that the external application is in contact with Universal Control.

1100 No speed from ISOBUS

No speed received from ISOBUS

1110 Too few Task Control server control channels. Check configuration.

Task Control does not support this machine configuration.

1120 Too few Task Control server configurations. Check configuration.

Task Control does not support this machine configuration.

1130 Too few Task Control server shares. Check configuration.

Task Control does not support this machine configuration.

1550 Fertiliser dust, SeedEye detector (row no.)

Dust/dirt in the sensor.

Clean the sensor.

1560 Fertiliser partially blocked, SeedEye detector (row no)

Sensor blocked.

Check the blockage between the detector and seed coulter.

1570 Fertiliser completely blocked, SeedEye detector (row no)

See alarm no. 1560.

1580 Fertiliser, low flow, SeedEye detector (row no.)

The amount of fertiliser detected is too low.

Troubleshoot for blocking before the sensor.

1590 Fertiliser, incorrect number of SeedEye detectors (expected, found)

The system cannot find the correct number of sensors, the system has found more sensors than expected.

1591 Fertiliser, missing a number of SeedEye detectors (expected, found)

The system cannot find the correct number of sensors, the system has found more sensors than expected.

1600 Fertiliser, lost SeedEye detector (row no.)

The system has lost contact with a sensor during operation.

1610 Fertiliser, low voltage, SeedEye detector

Some of the sensors have low voltages.

2050 Fertiliser, imbalance in SeedEye box (left, right)

One of the seed meters is delivering a greater amount of fertiliser than the other seed meter.

Adjust seed output. See 7.2 Fertiliser. Note that calibration must be carried out with SeedEye set to Monitoring.

2070 Fertiliser, low flow, Section

The amount of fertiliser in the section is too low.

Check the level in the seed hopper.

Check for a blockage before the sensors in the section.

Activation of the ‘low flow in entire section’ function may be applicable when drilling at extremely low application rates. See 11.5 Setting blockage sensitivity and flow sensitivity.

2071 Fertiliser, low flow, Section left

See alarm no. 2070.

2072 Fertiliser, low flow, Section right

See alarm no. 2070.

2073 Low flow, sections left and right

See alarm no. 2070.

3000 Missing distributor head

The system has lost contact with one or more CAN bus Flexheads. Check the wiring, plugs and connections to CAN bus Flexhead.

3010 Unknown distributor head

The system has made contact with one or more new CAN bus Flexheads. Configure the new CAN bus Flexheads.

3020 Distributor head: Update of device configuration failed

Configuration of CAN bus Flexhead was unsuccessful. Restart the system. Check if newer software is available for your machine.

3030 Distributor head, seed: Incorrect number of sockets {0} vs {1}

The installed CAN bus Flexhead does not match the machine’s configuration. Correct hardware must be installed.

3040 Distributor head, fertiliser: Incorrect number of sockets {0} vs {1}

The installed CAN bus Flexhead does not match the machine’s configuration. Correct hardware must be installed.

3050 Distributor heads not configured

CAN bus Flexheads must be configured.

3060 Distributor heads bad motor positions

The system has an incorrect number of rows. Restart the system.

3070 Distributor head, seed: requested motors not available {0}, available motors {1}

The distributor head has been commanded to close/open motors/hatches that do not exist (or are faulty). Check the tramlining program to make sure the correct ports have been set. If the alarm is triggered in connection with half machine shut-off or extended row spacing, the indicated motor is probably faulty.

3080 Distributor head, fertiliser: requested motors not available {0}, available motors {1}

The distributor head has been commanded to close/open motors/hatches that do not exist (or are faulty). Check the tramlining program to make sure the correct ports have been set. If the alarm is triggered in connection with half machine shut-off or extended row spacing, the indicated motor is probably faulty.

3090 Distributor head: {0} has lost contact with gateway – (Rejected)

One or more CAN bus Flexheads have restarted. Dismiss the alarm. If the alarm recurs repeatedly, check the wiring and connections to CAN bus Flexhead.

3100 Communication with distributor head(s) was temporarily busy

CAN bus Flexhead has not responded correctly. Restart the system.

3110 The distributor head motor command was not confirmed

A motor command has not been confirmed by CAN bus Flexhead. Restart the system.

3120 Upgrade of distributor head firmware failed

Upgrade of firmware for CAN bus Flexhead failed. Restart the system to try again.

3121 Upgrade of distributor head firmware failed {0}

Upgrade of firmware for CAN bus Flexhead failed. Restart the system to try again.

3122 Firmware package for distributor head not received, head {0}

Upgrade of firmware for CAN bus Flexhead failed. Restart the system to try again.

3123 Distributor head not ready for firmware update, head {0}

Upgrade of firmware for CAN bus Flexhead failed. Restart the system to try again.

3130 Distributor head stuck in boot loader, head {0}

One or more CAN bus Flexheads have not started. Restart the system.

3140 Distributor head, seed: motor {0} could not reach position

One or more of the hatches/motors cannot reach the correct position (open/closed). Check that the hatches are not blocked. The displayed number indicates the port for the blocked hatch in the distributor head.

3150 Distributor head, fertiliser: motor {0} could not reach position

One or more of the hatches/motors cannot reach the correct position (open/closed). Check that the hatches are not blocked. The displayed number indicates the port for the blocked hatch in the distributor head.

3160 Distributor head: low voltage head {0}

Low voltage to CAN bus Flexhead. Check the wiring, plugs and connections to CAN bus Flexhead.

3190 Distributor head forcibly opened

CAN bus Flexheads are manually set to open. This can be changed in the service menu.

3200 New device Unit ID not confirmed

CAN bus Flexhead has not been configured correctly. Restart the system and reconfigure it.

3210 Distributor head reported incorrect number of motors

CAN bus Flexhead is configured to have motors/hatches in all positions, but some are missing. Check the connections to the motors/hatches. If a motor has been manually removed, it is OK to run the system in this state, but no function will be available for the port/row for which a motor/hatch is missing.

3350 Seed depth sections misaligned

The seed coulter sections are not aligned. Stop the machine as soon as possible and run the alignment function to straighten the sections.

3360 Target value for the set seed depth not achieved

The hydraulic system is unable to reach the target seed depth.

3370 Sensor error seed depth seed coulters

 One of the seed coulter sensors is indicating an error.

3380 Sensor seed depth seed coulters reading incorrect value

One of the seed coulter sensors is indicating an error.

3390 Over current seed depth seed coulters

Valves or sensors connected to the WSX have too high current flow.

3400 Low voltage seed depth seed coulters

The sensors connected to the WSX have too low voltage.