6.2 General settings
For daily use no settings need to be entered in this menu.
Figure 1.
Speed for manual feed rate (km/h). Adapts the manual feed speed to the intended driving speed. If the expected driving speed is e.g. 7 km/h, the speed 7 km/h must be selected for manual feed.
Seed hopper modes.
Seed – Fertiliser
Seed - Seed
Specify whether the machine will be used for combination drilling (a) or whether the whole seed hopper will be used for seed (b).
(Applies to ST 600-900C only. When seed/seed is selected, fertiliser will be hidden in the UI).
K-value. Correction of an average deviation between the selected output quantity of fertiliser and the actual feed rate. (Applies to ST 600-900C only).
Example: Set amount: 360 kg/ha. Actual amount fed out: 400 kg/ha. 360/400=0.9. Change the K value to 0.9.
Fan shut-off ON/OFF. (Applies to STC only).
External Control is a GPS-based help function for use in the field. See 6.4 Task Control.
Increased row spacing ON/OFF. Can switch off even or odd rows. Only visible for fully equipped CAN bus Flexhead. When “Increased row spacing” is activated, tramlining will be switched off, and half machine shut-off will be disabled for ST400 and ST600InLine. The sown amount will not be reduced.
Shut-off. Even or odd rows.
Figure 2.
Row output, seed
Row output, fertiliser
If a custom setting for detectors for seed/fertiliser row output(G/H) is set, it can be factory reset by turning it off (off).
Seed/Fertiliser row output (G/H), see 6.2.1 Adapting the sensors to the seed feed.