9.2 Alarm list

Table 1. Alarms, function

Alarm Code

Function Name

Alarm Name

Description

1.4

Meter control

Overcurrent

  • The motor is consuming more current than it is rated for over too long time.

  • Check if something is jamming the feed motor.

  • If the problem persists without anything jamming the feed motor, the motor may need to be replaced.

1.5

Meter control

Shortcircuit

  • The motor has a shortcircuit.

  • Check the motor wiring harness.

  • If the problem persists, specialist attention is required.

1.9

Meter control

Sensor fault

  • The motor has incorrect connection of internal hall sensors.

  • Check the motor wiring harness. Most likely the motor needs to be changed.

1.12

Meter control

RPM high

  • The motor is running at >90 rpm.

  • Lower the speed.

  • Lower the rate.

  • Change the roller.

1.13

Meter control

Rpm low

  • The motor is running at <80% of its target rpm.

1.22

Meter control

Voltage low

  • There is a voltage drop either in the general 48V supply for the motor or in the internal wiring for the hall sensors.

  • Check power supply to the WSX.

1.29

Meter control

Not calibrated

  • Meter motor is missing calibration.

1.40

Meter control

Ground speed missing

  • No ground speed has been received, which is required to regulate feed output.

3.30

Bin level

Empty

  • The hopper is empty, as indicated by the sensor in the bottom of the hopper.

5.9

Air pressure

Sensor fault

  • The hopper pressure is sensor is broken.

5.10

Air pressure

Air pressure low

  • The hopper pressure is too low (<0.25 kPa) even though the fan is on.

  • Check that the hoppers are closed tight and that there is no damage to the hoppers.

  • Check that the air hose that supplies the hopper with air from the fan, is not damaged or blocked.

5.22

Air pressure

Voltage low

  • The sensor supply voltage is low

5.31

Air pressure

Pressure high

  • The hopper pressure is too high (>12kPa).

  • Turn off the fan and inspect the hoppers.

6.47

Ground speed

Degraded performance

  • When ISOBUS ground-based speed with fallback to ISOBUS wheel-based speed is selected and the speed has switched to fallback

6.64

Ground speed

Intermittent function

  • When changing to non-moving state, it is expected to still be in the non-moving state after 2 seconds, otherwise it is seen as a glitched value.

7.4

Agitator

Overcurrent

  • The motor is consuming more current than it is rated for over too long time.

  • Check if something is jamming the agitator.

  • If the problem persists without anything jamming the agitator, the motor may need to be replaced.

7.5

Agitator

Short circuit

  • The motor has a short circuit.

  • Check the motor wiring harness.

  • If the problem persists, specialist attention is required.

7.9

Agitator

Sensor fault

  • The motor has incorrect connection of internal hall sensors.

  • Check the motor wiring harness.

  • Most likely the motor needs to be changed.

7.22

Agitator

Voltage low

  • There is a voltage drop either in the general 12V supply for the motor or in the internal wiring for the hall sensors.

  • Check power supply to the WSX.

7.75

Agitator

Voltage low

  • The valve doesn’t seem to function, either it is not connected or malfunctioning.

8.12

Fan

Rpm high

  • Fan rpm is too high (configurable, default >6000 rpm).

8.13

Fan

Rpm low

  • Fan rpm is too low (configurable, default <2200 rpm) when the machine is unfolded and moving forward.

9.4

Power supply

Overcurrent

  • Overcurrent has been detected on one or more output ports to the PDB.

9.5

Power supply

Short circuit

  • Short circuit has been detected on one or more output ports to the PDB.

9.20

Power Supply

Battery drained

9.21

Power supply

Voltage high

  • The input voltage on alternator input to the PDB is > 54V.

9.22

Power supply

Voltage low

  • The 12V input voltage is < 9V or > 20V for more than 1 second during startup.

9.23

Power supply

Temperature high

  • High temperature has been detected on one or more output ports to the PDB.

9.47

Power supply

Degraded performance

  • When a system is configured with a fan on the same hydraulic circuit that drives the generator, and the fan has RPM but the power supply function does not report normal power mode

9.69

Power supply

Unexpected battery drain

  • When battery is discharging in low power mode

9.70

Power supply

Component failure

  • When battery is not charging in normal power mode when battery voltage is below 47V.

12.4

Worklight

Overcurrent

  • Overcurrent has been detected on one or more worklights.

  • Check wiring harness.

12.5

Worklight

Short circuit

  • Short circuit has been detected on one or more worklights.

  • Check wiring harness.

15.4

Load sense

Overcurrent

  • Overcurrent has been detected on one or more hydraulic valves connected with the load sense function.

  • Check wiring harness.

15.5

Load sense

Short circuit

  • Short circuit has been detected on one or more hydraulic valves.

  • Check wiring harness.

15.75

Load sense

Valve failure

  • When the valve driver hardware has shut off the valve due to short circuit.

16.4

Hitch weight transfer

Overcurrent

  • Overcurrent has been detected on one or more hydraulic valves connected with the load sense function.

  • Check wiring harness.

16.5

Hitch weight transfer

Short circuit

  • Short circuit has been detected on one or more hydraulic valves.

  • Check wiring harness.

16.10

Hitch weight transfer

Pressure low

  • Hydraulic pressure is low

16.31

Hitch weight transfer

Pressure high

  • Hydraulic pressure is high

16.75

Hitch weight transfer

Valve failure

  • The valve does not seem to function.

  • Not functioning

  • Malfunctioning

20.4

Wing pressure

Overcurrent

  • Overcurrent has been detected on one or more hydraulic valves connected with the load sense function.

  • Check wiring harness.

20.5

Wing pressure

Short circuit

  • Short circuit has been detected on one or more hydraulic valves.

  • Check wiring harness.

20.75

Wing pressure

Valve failure

  • The valve doesn’t seem to function, either it is not connected or malfunctioning.

23.4

Hydraulic tramline

Overcurrent

  • Overcurrent has been detected on one or more hydraulic valves connected with the load sense function.

  • Check wiring harness.

23.5

Hydraulic tramline

Short circuit

  • Short circuit has been detected on one or more hydraulic valves.

  • Check wiring harness.

23.75

Hydraulic tramline

Valve failure

  • The valve doesn’t seem to function, either it is not connected or malfunctioning.

36.4

Front disc

Overcurrent

  • Overcurrent has been detected on one or more hydraulic valves connected with the load sense function.

  • Check wiring harness.

36.5

Front disc

Short circuit

  • Short circuit has been detected on one or more hydraulic valves.

  • Check wiring harness.

36.9

Front disc

Sensor fault

  • Hydraulic sensor is broken, which will cause unregulated pressure on the front discs. Replace the sensor.

36.10

Front disc

Pressure low

  • Pressure is >5 bar below the setpoint.

36.31

Front disc

Pressure high

  • Pressure is >5 bar above the setpoint.

36.75

Front disc

Valve failure

  • The valve doesn’t seem to function, either it is not connected or malfunctioning.

37.4

Tine coulter

Overcurrent

  • Overcurrent has been detected on one or more hydraulic valves connected with the load sense function.

  • Check wiring harness.

37.5

Tine coulter

Short circuit

  • Short circuit has been detected on one or more hydraulic valves.

  • Check wiring harness.

37.9

Tine coulter

Sensor fault

  • Hydraulic sensor is broken, which will cause unregulated pressure on the front discs. Replace the sensor.

37.10

Tine coulter

Pressure low

  • Pressure is >5 bar below the setpoint.

37.31

Tine coulter

Pressure high

  • Pressure is >5 bar above the setpoint.

37.75

Tine coulter

Valve failure

  • The valve doesn’t seem to function, either it is not connected or malfunctioning.

39.17

Fan Control

Target not reached

  • The fan is unable to reach the set target, e.g., because the tractor cannot supply enough oil flow for the fan control block.

39.32

Fan control

Safety stop

  • No fan rpm received in time, stop the fan control.

40.6

Flexhead motor controller

Blockage

  • One or more of the hatches/motors cannot reach the correct position (open/closed).

  • Check that the hatches are not blocked.

  • The displayed number indicates the port for the blocked hatch in the distributor head.

40.22

Flexhead motor controller

Voltage low

  • External power supply voltage has dropped to <30V or there is >1.5V voltage loss between external power supply and the motor drive stage.

40.74

Flexhead motor controller

Motor failure

  • The motor has experienced some error (overtemperature, overcurrent, undervoltage, undercurrent).

47.6

Flow monitor

Blockage

  • SeedEye detector blocked.

  • Check the blockage between the detector and seed coulter.

47.9

Flow monitor

Sensor fault

  • SeedEye sensors has addressing errors, are not correctly updated or have different types.

  • Check the connection or replace the faulty detectors and readdress the system under Settings/SeedEye Configuration.

47.22

Flow monitor

Voltage low

  • Some of the sensors have low voltage.

  • Check the connections.

47.43

Flow monitor

Dusty sensor

  • Dust/dirt in the SeedEye sensor.

  • Clean the detector.

47.50

Flow monitor

Low flow

  • The number of counted seeds is too low.

  • If the alarm is given on a row, troubleshoot for blocking before the detector.

  • If the alarm is given on a section, check the level in the seed hopper.

  • Check for a blockage before the sensors in the section.

  • Activation of the low flow alarm on section may be applicable when drilling at extremely low application rates (see blockage/flow sensitivity setting).

47.51

Flow monitor

High flow

  • The number of counted seeds is too high (only row).

  • Check for a blockage around the sensor.

  • Check the set value of the application rate.

  • Too high a value will result in too many seeds passing the sensor.

47.52

Flow monitor

Unexpected flow

  • The SeedEye sensor has detected a flow when there should be no flow (when no seeding occurs).

  • Check if the hoses after the feed units are filled with material.

47.53

Flow monitor

Partial blockage

  • SeedEye detector blocked. Check the blockage between the detector and seed coulter.

47.54

Flow monitor

Sensor missing

  • The system has lost contact with a SeedEye sensor. Check the connections. Try readdressing the system.

50.55

Tramline

Motor missing

  • CAN FlexHead motor is missing to be able to perform the selected tramline program. Indicates which row is missing a motor.

54.2

Safety System

Communication disturbance

  • Missing replies from the safety system

54.9

Safety System

Sensor fault

  • A sensor in the safety system is failing.

54.24

Safety System

Device missing

Safety system device not present at startup or after soft reset.

54.40

Safety System

Ground speed missing

  • Safety system is missing wheel speed message.

54.46

Safety System

Safety system failure

  • Safety system has detected an internal critical error.

54.62

Safety System

Unexpected pressure

  • The safety system has detected an unexpected hydraulic pressure after closing safety valve.

54.75

Safety System

Valve failure

  • The valve doesn’t seem to function, either it is not connected or malfunctioning.

95.39

ISOBUS

Machine height missing

  • Timeout for machine height message on ISOBUS.

95.40

ISOBUS

Ground speed missing

  • Timeout for ground speed message on ISOBUS.

95.58

ISOBUS

Stop button pressed

  • An ISOBUS stop button is pressed.

95.67

ISOBUS

Connection aborted

  • Graphical Aux or Task Controller has reported an aborted connection with the implement for unknown reasons.

95.71

ISOBUS

Stop button error

  • An ISOBUS stop button has an error.

96.2

Gateway

Communication disturbance

  • CAN bus communication disturbance

96.20

Gateway

Battery drained

  • The gateway internal battery is drained.

96.27

Gateway

Communication failure

  • CAN bus communication failure.

96.56

Gateway

Battery nonfunctional

  • The gateway internal battery is nonfunctional.

97.1

Device

(Concerns only WSX48V)

Device unresponsive

  • The device is unresponsive.

97.2

Device

(Concerns both WSX48V and SeedEye)

Communication disturbance

  • CAN bus communication disturbance.

97.4

Device

(Concerns only SeedEye)

Overcurrent

  • Output current to the detectors is too high.

97.5

Device

(Concerns only SeedEye)

Short circuit

  • Short circuit detected on the power output to the detectors

97.9

Device

(Concerns only SeedEye)

Sensor fault

  • The detectors fail.

97.22

Device

(Concerns only SeedEye)

Voltage low

  • The input voltage, or the output voltage to the detectors is too low.

98.66

Task controller

Insufficient resources

  • The desired number of Task Controller booms and sections for Section Control and/or control channels for GEO is more than what is available on the server.

  • Check the TC information page for number of used/total resources used

98.68

Task controller

Incompatible configuration

  • While using ISOBUS-tramlining the Guidance Line Swath Width differs from the machine width in the Task Controller terminal.

98.72

Task controller

Early start

  • Assembly length compensation for TC-SC lookahead is degraded and caused an early feed start.

98.73

Task controller

Late start

  • Assembly length compensation for TC-SC lookahead is degraded and caused a late feed start.

Table 2. Alarms, device

Alarm Code

Device

Alarm Name

Description

99.24

Unspecfied

Device missing

  • An expected device on the machine is missing. If this coincides with 99.28 for the same device type, perform device identification.

  • Otherwise, ensure that the machine configuration is correct. If the machine configuration is correct a device may have permanently failed.

99.25

Unspecified

Firmware update failed

  • Firmware update of devices failed for some reason. If the problem persists after one restart, this requires specialist attention.

99.26

Unspecified

Configuration failed

  • Failed to configure the implement devices. Requires specialist attention, contact Väderstad if the problem persists after one reboot.

99.27

Unspecified

Communication failure

Device communication failed.

  • does not respond to 5 consecutive heartbeat requests, or

  • does not respond to an acknowledged message for 3 attempts, or

  • reports that its communication has failed due to missing configuration or heartbeats, or

  • does not respond with the expected report message after 10 re-sends during the startup sequence

99.28

Unspecified

Unknown device

  • An unknown device that is not mapped to a position on the machine, communicates with the system.

99.35

Unspecified

Unstable master terminal connection

  • Connection to the master terminal is unstable.

99.36

Unspecified

Master terminal lost

  • Connection to the master terminal is lost.

99.49

Unspecified

Unexpected restart

  • A device makes an unexpected restart.