Version |
Information |
|
5.1.1 |
Improvements Improved TC coverage precision when starting or stopping feed.
Increased the headland lock height threshold hysteresis for
carried machines. Added TC settings for if a function should be included in the
TC object pool or not.
Bug fixes Corrected FH dashboard symbol to spin when FH motors are active,
instead of when the machine is lowered to the seeding position. Corrected the bout markers to only be able to unfold when the
machine is lowered to the seeding position. Mounted machines with two machine height sensors shall now
consider the machine in ground as long as at least one sensor indicates
that. Avoid drawing TC tramline coverage for sections turned off
by section control. Avoid restarting the control system if the Isobus terminal
restarts. Fixed a bug where TC Singulation precision logging could be
incorrectly deactivated. Changing TC target rates will not cause false alarms of 'rate
low/high' or bad seeding statistics. Fixed a bug where TC did not properly downscale sections to
lower max number of sections. PCV with fertilizer without individual
row offset will now correctly set up 2 sections.
|
|
5.1.0 |
Improvements Alarm numbers and descriptions have been updated according
to new standard for Vaderstad machines. Added support for fertilizer option in-row/sideband for PCV.
Removed the PCV option to only use the rear half of the machine
(front half shall be used instead). Added support for variable rate per section or zone via TC.
Added support for logging of skips, doubles, downforce and
ground contact via TC. The singulator position can now be manually controlled from
the machine mode page and can be set while driving. Planting mode is now used for seed discs with up to 84 holes.
The PCV function Machine Attitude has been renamed to AutoLevel.
The FH on PCV can now run calibration even if PCV is in transport
mode. Ground contact information is now available also for central
hydraulic row unit downforce systems with sensors. After running seed on the calibration page, the resulting singulator
position is also applied on other rows configured with auto-singulator.
Updated tramline symbol; green indicates that the tramline
track is counted as seeded, while white indicates that it is not counted
as seeded. Introduced a 10 second delay on hopper level alarms to avoid
alarms on short glitches.
Bug fixes Only count statistics for driven and planted time when having
speed Avoid drawing tramline coverage outside TC bounds. Correction of default TC lateral offset when configuring PCV
for 12 rows. Prefill of fertilizer, microgranulate and Biodrill now starts
when pushing, instead of releasing, the button.
|
|
5.0.7 |
|
|
5.0.6 |
|
|
5.0.5 |
New features Added support for machine type Proceed V Added support for WSX based TPL with Liquid Fertilizer Support for update of seeded/driven area from e-tech 2.0
Improvements When configuring an additional product (e.g. BioDrill), the
product will by default now be added to Manual feed group A. The CAN-adapter connected to ACU6 is now automatically detected
after the USB-cable has been disconnected/ reconnected. Machines with row units on different offsets in driving direction
(e.g. Tempo K and Proceed V) can now specify if the TC offsets for
a product (seed, fertilizer, etc.) shall be on individual level (requires
support for more sections in the TC controller) or if all row units
for the product shall be handled with a common offset. Bin level alarms are no longer displayed when in transport
mode. The US and Imperial unit systems on VT have been merged, so
that Imperial covers both. Only applicable settings per machine type are now visible on
the machine setup page to avoid an incompatible configuration.
Bug fixes Toggling rows on/off from right via the ISOBUS Aux function
has been corrected. The manual feed button could get stuck until switching of the
machine if using “right-click” multi-touch equivalent. This has now
been corrected. Correction of maximum value for TC section control turn on/off
times. The alarm count on VT dashboard header by mistake included
also dismissed and overridden alarms. This has now been corrected.
The alarm history was not persistently stored. This has now
been corrected.
|
|
5.0.2 |
Support WSX HW Gen2 (FCC approved). The PDB now disconnects the battery when the generator stops,
to avoid discharging the battery.
|
|
5.0.1 |
Initial release |