18.5 Alarm list for liquid fertiliser
-
723. Liquid fertiliser system pressure too low
-
Check that there is no air in the system. If so, run fill program.
The system pressure sensor may give an incorrect signal.
-
724. Liquid fertiliser system pressure too high
-
The system pressure sensor may give an incorrect signal.
-
729. Liquid fertiliser fill valve undercurrent
-
The fill valve is drawing too low a current.
Check the valve, cables, connectors and connections.
-
730. Liquid fertiliser pump control valve undercurrent
-
The fill valve is drawing too low a current.
Check the valve, cables, connectors and connections.
-
731. Liquid fertiliser circulation valve undercurrent
-
The circulation valve is drawing too low a current.
Check the valve, cables, connectors and connections.
-
732. Liquid fertiliser dosing valve A undercurrent
-
Dosing valve A is drawing too low a current.
Check the valve, cables, connectors and connections.
-
733. Liquid fertiliser tank level detector fault
-
Check the sensor’s cable, contacts and connections.
The sensor may be defective.
-
735. Liquid fertiliser system pressure detector fault
-
Check the sensor’s cable, contacts and connections.
The sensor may be defective.
-
738. Liquid fertiliser low pump speed
-
The pump is not reaching the target speed.
Check that there is hydraulic flow in the pump.
-
739. Liquid fertiliser no pump flow
-
Check that there is no obstruction in the flow system.
Check that the pressure valve is not closed. If it is closed, run the pressure valve reset program.
-
741. Liquid fertiliser low feed rate
-
The machine is unable to achieve the set feed rate.
Check that the correct dosing nozzle sizes are set and installed.
Reduce the speed and drive more slowly.
Switch to larger dosing nozzles.
-
742. Liquid fertiliser tank level too low
-
The tank level is below the set minimum alarm level.
Fill the tank or lower the alarm level.
-
743. Liquid fertiliser dosing valve B undercurrent
-
Dosing valve B is drawing too low a current.
Check the valve, cables, connectors and connections.
-
744. Connection to WorkStation liquid fertiliser dosing has been lost
-
Check the connector cable to liquid fertiliser dosing WS.
-
745. Connection to WorkStation liquid fertiliser dosing has been restored
-
Check the power and CANBUS cables to liquid fertiliser dosing WS.
-
746. WorkStation liquid fertiliser dosing is missing
-
Check cables to liquid fertiliser dosing WS.
-
747. Liquid fertiliser high feed rate
-
The machine cannot reach a low enough feed rate.
Check that the correct dosing nozzle sizes are set and installed.
Increase your speed and drive faster.
Switch to smaller dosing nozzles.
-
748. Liquid fertiliser pressure detector suction filter fault
-
Check the sensor’s cable, contacts and connections.
The sensor may be defective.
-
749. Liquid fertiliser no flow suction filter
-
Check that the suction filter is not clogged.
-
752. Connection to WorkStation liquid fertiliser has been lost
-
Check the connector cable to liquid fertiliser WS.
-
753. Connection to WorkStation liquid fertiliser has been restored
-
Check the power and CANBUS cables to liquid fertiliser WS.
-
754. WorkStation liquid fertiliser is missing
-
Check cables to liquid fertiliser WS.