2.6.1 Button functions

Figure 1.

  1. Variable adjustable seed feed rate: hold down the A button and move UP/DOWN using the E and H buttons.

    Activate or deactivate row units from left: hold down button A and press F.

    Activate or deactivate row units from right: hold down button A and press G.

  2. Variable adjustable fertiliser feed rate: hold down the B button and move UP/DOWN using the E and H buttons.

  3. Alarms menu (displayed as long as the button is held down).

  4. Statistics menu (displayed as long as the button is held down).

    A maximum of 12 row units may be displayed at a time. If there are more than 12 row units, move RIGHT/LEFT using the F and G buttons while holding down the D button

  5. Lift stop (OFF/ON).

  6. Not used.

  7. Bout marker switching. Switches manually or automatically depending on selection with the function button.

  8. Manual feed.